Patio Heater BTU Calculator
Enter the area you want warm and choose gas or electric. The result is the range of heater input implied by the coverage figures manufacturers publish, and every model behind it is listed below.
Result
Heater input for your area
28,000 to 53,300 Btu/h
- Lowest published coverage rate
- 140.0 Btu/h per sq ft (Schwank supremeSchwank 2300 Series, 35K)
- Highest published coverage rate
- 266.7 Btu/h per sq ft (Schwank phantomSchwank STP Series, 80K)
- Heater models counted
- 10 gas models from 2 manufacturers (Bromic, Schwank)
Notes on This Result
- Cold or windy sites can need more heat than the average coverage figures assume. Schwank says its heaters may cover less than the average area in extremely cold or windy conditions, and does not publish a number for how much less.
- Wind also cuts a gas heater's performance. Bromic's manual says its Tungsten gas heater is designed for winds up to 10 mph. Its product page says 8 mph. We cite the manual.
- A fixed gas heater needs a gas supply sized for its input. Check your line with the gas line sizing tool before you buy.
Calculation Details
Formula
Range = your area × the lowest and highest output per square foot found in manufacturers' published heated areas for that heater type.
Assumptions
- There is no standard for how much heat an outdoor space needs. This range comes from the heated area each manufacturer publishes for its own heaters, divided into the heater's rated input.
- Manufacturers measure coverage differently and at different mounting heights, which is why the range is wide. The low end is the most generous coverage claim we found. The high end is the most conservative.
- Sheltered spaces need less than the figures suggest and cold, windy ones need more, by the manufacturers' own notes. None of them publishes a number for how much.
- Patio heaters warm people, not air. A well-designed installation feels about 3 to 7 degrees warmer at 60°F, by testing Infratech cites. Do not expect a covered patio to feel like indoors.
- Gas fire pits and fire tables are not rated for heating an area, so this does not size one.
Sources
Bromic, Product Cut Sheet Tungsten Gas (PDF dated 2026-01-22), Specifications table, Heat Area, footnote 'In ideal conditions'; rated input from the Tungsten Smart-Heat Gas product page option list (https://www.bromic.com/product/tungsten-smart-heat-gas/)
Checked . View at bromic.com.
Bromic, Platinum Smart-Heat Gas product page specification table (Heat Area, Output) and Product Cut Sheet Platinum Gas (https://pim.bromic.com/wp-content/uploads/2026/02/Product-Cut-Sheet-Platinum-Gas-1.pdf)
Checked . View at bromic.com.
Schwank, Compare Schwank Patio Heater Models (manufacturer page), Coverage Area row; coverage stated at a mounting height of 10 ft
Checked . View at schwankgroup.com.
Infratech, Choosing your Infratech system chart (IN999_gettingstarted_chart, PDF dated 2025-01-28), Heat Coverage Area and Mounting Height rows
Checked . View at infratech.com.
Infratech, FAQs, 'How much heat should I expect?': a good patio heat installation provides 3 to 7 degrees of perceived heat at 60 F ambient; more than 7 is too warm to sit in for extended periods. Infratech attributes this to Pacific Gas & Electric's Food Service Technology Center
Checked . View at infratech.com.
Bromic, Tungsten Smart-Heat Gas Instruction Manual, Version 2.3 USA / Canadian, Installation Requirements, PDF p. 6: the heater is designed to function in winds up to 10 mph
Checked . View at pim.bromic.com.
Bromic, Tungsten Smart-Heat Gas product page: wind resistance of up to 8 mph
Checked . View at bromic.com.
Heater Models Behind the Range
Each row is one heater model and the heated area its manufacturer publishes for it. The range in the result runs from the lowest to the highest input per square foot in these tables. Find the heater you are considering to see where it sits.
Gas patio heaters, rated input in Btu/h
Bromic Tungsten Smart-Heat Gas 300Source: Bromic Tungsten Smart-Heat Gas 300
- Rated input
- 26,000 Btu/h
- Heated area
- 160 sq ft
- Input per sq ft
- 162.5
- Basis for the coverage
- Bromic marks its heat area 'In ideal conditions'
Bromic Tungsten Smart-Heat Gas 500Source: Bromic Tungsten Smart-Heat Gas 500
- Rated input
- 43,000 Btu/h
- Heated area
- 215 sq ft
- Input per sq ft
- 200.0
- Basis for the coverage
- Bromic marks its heat area 'In ideal conditions'
Bromic Platinum Smart-Heat Gas 300Source: Bromic Platinum Smart-Heat Gas 300
- Rated input
- 23,600 Btu/h
- Heated area
- 160 sq ft
- Input per sq ft
- 147.5
- Basis for the coverage
- Bromic marks its heat area 'In ideal conditions'
Bromic Platinum Smart-Heat Gas 500Source: Bromic Platinum Smart-Heat Gas 500
- Rated input
- 39,800 Btu/h
- Heated area
- 215 sq ft
- Input per sq ft
- 185.1
- Basis for the coverage
- Bromic marks its heat area 'In ideal conditions'
Schwank supremeSchwank 2300 Series, 23KSource: Schwank supremeSchwank 2300 Series, 23K
- Rated input
- 23,000 Btu/h
- Heated area
- 150 sq ft
- Input per sq ft
- 153.3
- Basis for the coverage
- Schwank states coverage at a 10 ft mounting height
Schwank supremeSchwank 2300 Series, 35KSets the low end of the rangeSource: Schwank supremeSchwank 2300 Series, 35K
- Rated input
- 35,000 Btu/h
- Heated area
- 250 sq ft
- Input per sq ft
- 140.0
- Basis for the coverage
- Schwank states coverage at a 10 ft mounting height
Schwank supremeSchwank 2300 Series, 50KSource: Schwank supremeSchwank 2300 Series, 50K
- Rated input
- 50,000 Btu/h
- Heated area
- 350 sq ft
- Input per sq ft
- 142.9
- Basis for the coverage
- Schwank states coverage at a 10 ft mounting height
Schwank phantomSchwank STP Series, 50KSource: Schwank phantomSchwank STP Series, 50K
- Rated input
- 50,000 Btu/h
- Heated area
- 200 sq ft
- Input per sq ft
- 250.0
- Basis for the coverage
- Schwank states coverage at a 10 ft mounting height
Schwank phantomSchwank STP Series, 80KSets the high end of the rangeSource: Schwank phantomSchwank STP Series, 80K
- Rated input
- 80,000 Btu/h
- Heated area
- 300 sq ft
- Input per sq ft
- 266.7
- Basis for the coverage
- Schwank states coverage at a 10 ft mounting height
Schwank phantomSchwank STP Series, 115KSource: Schwank phantomSchwank STP Series, 115K
- Rated input
- 115,000 Btu/h
- Heated area
- 500 sq ft
- Input per sq ft
- 230.0
- Basis for the coverage
- Schwank states coverage at a 10 ft mounting height
Electric patio heaters, rated input in watts
Infratech C-15 / W-15Source: Infratech C-15 / W-15
- Rated input
- 1,500 W
- Heated area
- 25 sq ft
- Input per sq ft
- 60.0
- Basis for the coverage
- 5 ft x 5 ft; Infratech chart pairs this coverage with a 6 to 7 ft mounting height
Infratech SL-16Sets the high end of the rangeSource: Infratech SL-16
- Rated input
- 1,600 W
- Heated area
- 25 sq ft
- Input per sq ft
- 64.0
- Basis for the coverage
- Same coverage group as the C-15 in the chart
Infratech C-20 / W-20Source: Infratech C-20 / W-20
- Rated input
- 2,000 W
- Heated area
- 36 sq ft
- Input per sq ft
- 55.6
- Basis for the coverage
- 6 ft x 6 ft; Infratech chart pairs this coverage with a 7 to 8 ft mounting height
Infratech C-26 / W-26Source: Infratech C-26 / W-26
- Rated input
- 2,600 W
- Heated area
- 56 sq ft
- Input per sq ft
- 46.4
- Basis for the coverage
- 7 ft x 8 ft; Infratech chart pairs this coverage with a 7 to 8 ft mounting height
Infratech CD-30 / WD-30Source: Infratech CD-30 / WD-30
- Rated input
- 3,000 W
- Heated area
- 49 sq ft
- Input per sq ft
- 61.2
- Basis for the coverage
- 7 ft x 7 ft; Infratech chart pairs this coverage with a 7 to 8 ft mounting height
Infratech SL-24Source: Infratech SL-24
- Rated input
- 2,400 W
- Heated area
- 49 sq ft
- Input per sq ft
- 49.0
- Basis for the coverage
- Same coverage group as the CD-30 in the chart
Infratech C-30 / SL-30 / W-30Source: Infratech C-30 / SL-30 / W-30
- Rated input
- 3,000 W
- Heated area
- 64 sq ft
- Input per sq ft
- 46.9
- Basis for the coverage
- 8 ft x 8 ft; Infratech chart pairs this coverage with a 7 to 9 ft mounting height
Infratech C-40 / SL-40 / W-40Source: Infratech C-40 / SL-40 / W-40
- Rated input
- 4,000 W
- Heated area
- 100 sq ft
- Input per sq ft
- 40.0
- Basis for the coverage
- 10 ft x 10 ft; Infratech chart pairs this coverage with an 8 to 10 ft mounting height
Infratech CD-40 / WD-40Source: Infratech CD-40 / WD-40
- Rated input
- 4,000 W
- Heated area
- 80 sq ft
- Input per sq ft
- 50.0
- Basis for the coverage
- 8 ft x 10 ft; Infratech chart pairs this coverage with an 8 to 10 ft mounting height
Infratech CD-52 / WD-52Source: Infratech CD-52 / WD-52
- Rated input
- 5,200 W
- Heated area
- 100 sq ft
- Input per sq ft
- 52.0
- Basis for the coverage
- 10 ft x 10 ft; Infratech chart pairs this coverage with an 8 to 10 ft mounting height
Infratech CD-60 / WD-60Source: Infratech CD-60 / WD-60
- Rated input
- 6,000 W
- Heated area
- 121 sq ft
- Input per sq ft
- 49.6
- Basis for the coverage
- 11 ft x 11 ft; Infratech chart pairs this coverage with an 8 to 12 ft mounting height
Bromic Tungsten Smart-Heat Electric 2000WSource: Bromic Tungsten Smart-Heat Electric 2000W
- Rated input
- 2,000 W
- Heated area
- 65 sq ft
- Input per sq ft
- 30.8
- Basis for the coverage
- Cut sheet heat area
Bromic Tungsten Smart-Heat Electric 3000WSource: Bromic Tungsten Smart-Heat Electric 3000W
- Rated input
- 3,000 W
- Heated area
- 100 sq ft
- Input per sq ft
- 30.0
- Basis for the coverage
- Cut sheet heat area
Bromic Tungsten Smart-Heat Electric 4000WSource: Bromic Tungsten Smart-Heat Electric 4000W
- Rated input
- 4,000 W
- Heated area
- 130 sq ft
- Input per sq ft
- 30.8
- Basis for the coverage
- Cut sheet heat area
Bromic Tungsten Smart-Heat Electric 6000WSource: Bromic Tungsten Smart-Heat Electric 6000W
- Rated input
- 6,000 W
- Heated area
- 160 sq ft
- Input per sq ft
- 37.5
- Basis for the coverage
- Cut sheet heat area
Bromic Eclipse Smart-Heat ElectricSource: Bromic Eclipse Smart-Heat Electric
- Rated input
- 2,900 W
- Heated area
- 121 sq ft
- Input per sq ft
- 24.0
- Basis for the coverage
- Cut sheet heat area
Schwank eSchwank Ghost ESM, 4kWSource: Schwank eSchwank Ghost ESM, 4kW
- Rated input
- 4,000 W
- Heated area
- 160 sq ft
- Input per sq ft
- 25.0
- Basis for the coverage
- Schwank states coverage at a 10 ft mounting height
Schwank eSchwank Ghost ESM, 6kWSource: Schwank eSchwank Ghost ESM, 6kW
- Rated input
- 6,000 W
- Heated area
- 200 sq ft
- Input per sq ft
- 30.0
- Basis for the coverage
- Schwank states coverage at a 10 ft mounting height
Schwank eSchwank Electric ES/ESD, 2kWSets the low end of the rangeSource: Schwank eSchwank Electric ES/ESD, 2kW
- Rated input
- 2,000 W
- Heated area
- 100 sq ft
- Input per sq ft
- 20.0
- Basis for the coverage
- Schwank states coverage at a 10 ft mounting height
Schwank eSchwank Electric ES/ESD, 4kWSource: Schwank eSchwank Electric ES/ESD, 4kW
- Rated input
- 4,000 W
- Heated area
- 140 sq ft
- Input per sq ft
- 28.6
- Basis for the coverage
- Schwank states coverage at a 10 ft mounting height
Schwank eSchwank Electric ES/ESD, 6kWSource: Schwank eSchwank Electric ES/ESD, 6kW
- Rated input
- 6,000 W
- Heated area
- 160 sq ft
- Input per sq ft
- 37.5
- Basis for the coverage
- Schwank states coverage at a 10 ft mounting height
What the Result Means
The result is a range of heater input, not a recommendation. The low end comes from the most generous coverage claim we found and the high end from the most conservative one, which is why the two ends sit far apart. Find the heater you are considering in the tables below the calculator. A heater near the low end is counting on its manufacturer's best-case coverage. A heater near the high end is making the cautious claim.
Mounting height changes the coverage. Infratech and Schwank both tie each coverage figure to a mounting height, and a heater mounted higher covers more area less intensely. Wind and cold reduce it: both say their heaters can cover less than average in extremely cold or windy conditions, and neither says by how much. Bromic's manual says its Tungsten gas heater is designed for winds up to 10 mph. Shelter works the other way, and well-protected spaces generally get more than the average coverage.
Plan to warm people, not the air. Infratech cites testing that puts a good installation at 3 to 7 degrees of perceived heat at 60°F, and says more than 7 is too warm to sit in for long. Even a covered patio will not feel like indoors.
This calculator does not size a fire pit or a fire table, because they are not rated for heating an area.
Call a licensed installer or electrician in three cases. Bromic limits gas heaters to open-air situations and sets minimum open wall areas for covered, walled spaces, so a patio near that line needs a site visit. A fixed gas heater needs a gas supply sized for its input, which is licensed work. Start with the gas line sizing calculator. Electric heaters of 4 kW and up run on 208 to 277 V circuits, so have an electrician size the circuit. Infratech and Bromic both offer layout design for a specific patio.